MTL5046 ISOLATING DRIVER 4/20mA, smart, with line fault detection The MTL5046 accepts a 4/20mA signal from a controller located in the safe area to drive a load in the hazardous area. It permits bi-directional transmission of digital s
产品特点 产品参数 安装方法 技术资料
订购热线:
021-51090808
MTL5046 ISOLATING
DRIVER
4/20mA, smart,
with line fault detection
The MTL5046 accepts a 4/20mA signal from a controller located
in the safe area to drive a load in the hazardous area. It permits
bi-directional transmission of digital signals to and from an operator
station or hand-held communicator. A line fault detection (LFD)  facility
is also provided.

 
 
SPECIFICATION
See also common specification
One Location of load Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
Safe-area input
Signal range: 4 to 20mA
Under/over-range: 1 to 24mA
Hazardous-area output
Load resistance: minimum 100
maximum 800Ω(16V at 20mA)
Digital signal bandwidth
500Hz to 10kHz
Output resistance
>2MΩ
Input and output circuit ripple
<40µA peak-to-peak
Transfer accuracy at 20°C
Input voltage drop
<4V at 20mA
Response time
Settles to within 10% of final value within 100µs、
Temperature drift
<0.5µA/°C
Line fault detection (LFD)
Signalled by an impedance change in the safe-area loop.
When a line fault occurs, the impedance between pins
11 and 12 is >100kΩ
LED indicator
Green: power indication
Supply voltage
20 to 35V dc
Maximum current consumption (with 20mA signal)
65mA at 24V
75mA at 20V
50mA at 35V
Maximum power dissipation within unit (with 20mA signal)
1.5W at 24V
1.6W at 35V
Safety description
28V, 300Ω93mA; U m = 250V rms or dc
 
 
 
SPECIFICATION
See also common specification
One Location of load Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
Safe-area input
Signal range: 4 to 20mA
Under/over-range: 1 to 24mA
Hazardous-area output
Load resistance: minimum 100
maximum 800Ω(16V at 20mA)
Digital signal bandwidth
500Hz to 10kHz
Output resistance
>2MΩ
Input and output circuit ripple
<40µA peak-to-peak
Transfer accuracy at 20°C
Input voltage drop
<4V at 20mA
Response time
Settles to within 10% of final value within 100µs、
Temperature drift
<0.5µA/°C
Line fault detection (LFD)
Signalled by an impedance change in the safe-area loop.
When a line fault occurs, the impedance between pins
11 and 12 is >100kΩ
LED indicator
Green: power indication
Supply voltage
20 to 35V dc
Maximum current consumption (with 20mA signal)
65mA at 24V
75mA at 20V
50mA at 35V
Maximum power dissipation within unit (with 20mA signal)
1.5W at 24V
1.6W at 35V
Safety description
28V, 300Ω93mA; U m = 250V rms or dc
 

 